HVAC & Water Heater Service in Belleville, MI | Schedule Now
$79 Furnace and AC Tune-Up BOGO Tune-Ups Buy One Tune-up and Get the Other Free! Request Service

Top-Rated HVAC & Water Heater Services in Belleville

Serving Belleville since 1998, family-owned Iceberg Heating & Cooling provides top-quality heating, cooling, water heater, and air quality services to keep you comfortable and safe through the seasons. From emergency heating repairs on a frigid, windy day in January to seasonal air conditioning maintenance in the spring, Iceberg Heating & Cooling has got all your home comfort needs covered — and a 100% satisfaction guarantee backs all our work!

Give your Belleville, MI, home the gift of comfort by scheduling top-rated services with Iceberg Heating & Cooling today!

 

The hood of an Iceberg Heating  & Cooling work truck with the company logo

 

24/7 Emergency Heating Repair & Replacement

A heated home is necessary in Belleville, and your heating repairs and replacements are a top priority at Iceberg Heating & Cooling. We proudly provide 24/7 heating services to meet all your heating needs for boilers, furnaces, heat pumps, and packaged units. Or top-rated heating services include:

  • Installation and replacement: If your heating system is getting old and showing signs of age, including high energy bills, strange noises/smells, uneven heating, weak airflow, or lack of warm air, it’s time to upgrade to a high-efficiency heating system.
  • Repair: Our expert HVAC technicians provide top-notch heating repairs in Belleville. Common heating problems we fix include clogged filters, pilot light issues, boiler leaks, faulty ignitions, broken thermostats, and heaters that won’t turn on.
  • Maintenance: Scheduling heating maintenance is the smartest move for your heating system. It will save you money and stress by helping you avoid emergency breakdowns and decreasing your energy bills.

Expert Air Conditioning & Cooling Services

With an A+ rating from the Better Business Bureau, Iceberg Heating & Cooling provides top-notch cooling services in Belleville for central AC systems, ductless mini-splits, and heat pumps. Our trusted air conditioning services include:

  • Installation and replacement: Need 24/7 HVAC services in August? We got you! Signs you need air conditioning replacement include frequent broken parts/expensive repairs, a lack of cool air, your AC won’t turn on, frequent short-cycling, high energy bills, and uneven cooling.
  • Repair: Call us for expert air conditioning repair when your AC doesn’t turn on, blows warm air or weak airflow, makes strange noises or smells, the thermostat isn’t working, or leaks.
  • Maintenance: Scheduling expert AC maintenance with us saves you from the hassle of emergency breakdowns while helping your AC last longer and work more efficiently.

Indoor Air Quality Services in Belleville

Does your home smell musty, or do your allergies mysteriously flare up when you’re inside? Your indoor air quality could be compromised. To help you breathe easier, Iceberg Heating & Cooling proudly provides industry-best air quality services for Belleville homes, including:

  • Dehumidifiers: Musty homes with damp basements or areas prone to mold benefit significantly from installing whole-home dehumidifiers. 
  • Humidifiers: Ideal for the dry winter months in Michigan when heaters are on full-blast, whole-home humidifiers help restore much-needed moisture to the air.
  • Air purifiers: Whole-home air purifiers help remove unwanted contaminants from the air, including pet dander, dust, viruses, bacteria, and mold. 
  • Air ducts: We clean, replace, and repair dirty, clogged, and damaged air ducts to keep the air flowing throughout your HVAC system clean and pristine.

Unmatched Water Heater Services

Iceberg Heating & Cooling provides 24/7 and same-day water heater services in Belleville for traditional and tankless water heaters. Our top-rated water heater services include:

  • Installation and replacement: Is your water heater tank rusty, corroded, and leaking? It could be time to replace it.
  • Repair: Call us ASAP if you lose hot water, your water heater makes strange noises or smells, or your tank leaks.
  • Maintenance: We provide the most thorough water heater maintenance services in Belleville, including flushing your tank, testing the thermostat, and inspecting the temperature and pressure valve.

Schedule Services With Iceberg Heating & Cooling in Belleville, MI

Customer service is everything at Iceberg Heating & Cooling. That’s why our licensed and insured technicians strive to provide the highest level of service on every job. We also guarantee:

Contact the Iceberg Heating & Cooling team today to schedule your free service estimate in Belleville, MI.

Recent Jobs and Reviews in Belleville , MI

Job Locations and Reviews

# HVAC Maintenance Agreement Visit - Air Conditioner Tune-Up Completed

Performed comprehensive preventive maintenance on residential air conditioning system as part of prepaid maintenance agreement. No operational issues or concerns reported prior to service visit.

## Work Performed

Conducted complete air conditioner tune-up and inspection on indoor air handler unit located in basement mechanical room. Performed visual inspection of all accessible components including refrigerant line insulation, electrical connections, and condensate drainage system. Verified proper installation of vibration dampeners and flexible connectors on refrigerant lines. Inspected copper refrigerant piping with white insulation wrap secured with mounting straps for any signs of damage or deterioration.

Examined manufacturer information plate and verified system specifications. Assessed condition of PVC condensate drain lines and fittings for proper drainage and potential blockages. Checked air handler cab
# HVAC Maintenance Agreement Visit - Air Conditioner Tune-Up Completed

Performed comprehensive preventive maintenance on residential air conditioning system as part of prepaid maintenance agreement. No operational issues or concerns reported prior to service visit.

## Work Performed

Conducted complete air conditioner tune-up and inspection on indoor air handler unit located in basement mechanical room. Performed visual inspection of all accessible components including refrigerant line insulation, electrical connections, and condensate drainage system. Verified proper installation of vibration dampeners and flexible connectors on refrigerant lines. Inspected copper refrigerant piping with white insulation wrap secured with mounting straps for any signs of damage or deterioration.

Examined manufacturer information plate and verified system specifications. Assessed condition of PVC condensate drain lines and fittings for proper drainage and potential blockages. Checked air handler cab
IC S.
IC S. Checked in
# HVAC Maintenance Agreement Visit - Air Conditioner Tune-Up Completed Performed comprehensive preventive maintenance on residential air conditioning system as part of prepaid maintenance agreement. No operational issues or concerns reported prior to service visit. ## Work Performed Conducted complete air conditioner tune-up and inspection on indoor air handler unit located in basement mechanical room. Performed visual inspection of all accessible components including refrigerant line insulation, electrical connections, and condensate drainage system. Verified proper installation of vibration dampeners and flexible connectors on refrigerant lines. Inspected copper refrigerant piping with white insulation wrap secured with mounting straps for any signs of damage or deterioration. Examined manufacturer information plate and verified system specifications. Assessed condition of PVC condensate drain lines and fittings for proper drainage and potential blockages. Checked air handler cab
Belleville, MI 48111
Completed warranty work for crawl space portion of HVAC installation. Performed system diagnostics using digital manifold gauge set, verifying refrigerant pressures at service ports on copper line set with proper brass fittings and insulated suction and liquid lines. Confirmed proper installation of air handler unit in mechanical space with complete condensate drainage system using PVC piping with appropriate primer application at all joints, condensate safety switch properly mounted and secured, and metal ductwork correctly installed with proper support strapping.
Completed warranty work for crawl space portion of HVAC installation. Performed system diagnostics using digital manifold gauge set, verifying refrigerant pressures at service ports on copper line set with proper brass fittings and insulated suction and liquid lines. Confirmed proper installation of air handler unit in mechanical space with complete condensate drainage system using PVC piping with appropriate primer application at all joints, condensate safety switch properly mounted and secured, and metal ductwork correctly installed with proper support strapping.
IC S.
IC S. Checked in
Completed warranty work for crawl space portion of HVAC installation. Performed system diagnostics using digital manifold gauge set, verifying refrigerant pressures at service ports on copper line set with proper brass fittings and insulated suction and liquid lines. Confirmed proper installation of air handler unit in mechanical space with complete condensate drainage system using PVC piping with appropriate primer application at all joints, condensate safety switch properly mounted and secured, and metal ductwork correctly installed with proper support strapping.
Belleville, MI 48111
Successfully completed installation of a 2.5 ton air conditioning system with matching evaporator coil at residential property. Unit was positioned in rear yard location with electrical reconnection performed to code. All mechanical and electrical connections were secured, system was tested for proper operation, and site was left clean and ready for customer use.
Successfully completed installation of a 2.5 ton air conditioning system with matching evaporator coil at residential property. Unit was positioned in rear yard location with electrical reconnection performed to code. All mechanical and electrical connections were secured, system was tested for proper operation, and site was left clean and ready for customer use.
IC S.
IC S. Checked in
Successfully completed installation of a 2.5 ton air conditioning system with matching evaporator coil at residential property. Unit was positioned in rear yard location with electrical reconnection performed to code. All mechanical and electrical connections were secured, system was tested for proper operation, and site was left clean and ready for customer use.
Belleville, MI 48111
Completed mechanical installation of 3-ton air conditioning system with matching evaporator coil in rear yard location. Installed new indoor air handler unit in basement mechanical room, connected refrigerant lines, established electrical connections, and mounted smart thermostat for system control.
Completed mechanical installation of 3-ton air conditioning system with matching evaporator coil in rear yard location. Installed new indoor air handler unit in basement mechanical room, connected refrigerant lines, established electrical connections, and mounted smart thermostat for system control.
IC W.
IC W. Checked in
Completed mechanical installation of 3-ton air conditioning system with matching evaporator coil in rear yard location. Installed new indoor air handler unit in basement mechanical room, connected refrigerant lines, established electrical connections, and mounted smart thermostat for system control.
Belleville, MI 48111
Belleville, MI - Performed scheduled HVAC maintenance agreement visit for AC and system inspection. Upon inspection of the air handler unit, documented heavily soiled mesh filter media within the ductwork plenum showing significant accumulation of dust, debris, and particulate matter with dark streaking patterns. Verified integrity of reflective foil-faced duct insulation and vapor barrier. Photographed system conditions for maintenance records. System operational at time of departure.
IC M.
IC M. Checked in
Performed scheduled HVAC maintenance agreement visit for AC and system inspection. Upon inspection of the air handler unit, documented heavily soiled mesh filter media within the ductwork plenum showing significant accumulation of dust, debris, and particulate matter with dark streaking patterns. Verified integrity of reflective foil-faced duct insulation and vapor barrier. Photographed system conditions for maintenance records. System operational at time of departure.
Belleville, MI 48111
Conducted estimate for R22 refrigerant system with reported flat/no cooling condition. Inspected Nest thermostat installation and wiring configuration, documenting terminal connections including Y1, Y2, G, RC, W1/E, W2/AUX, and C terminals with multiple blue wires and red wire properly connected. Evaluated basement mechanical area with exposed HVAC ductwork and electrical infrastructure to assess system accessibility and replacement requirements for aging R22 equipment.
Conducted estimate for R22 refrigerant system with reported flat/no cooling condition. Inspected Nest thermostat installation and wiring configuration, documenting terminal connections including Y1, Y2, G, RC, W1/E, W2/AUX, and C terminals with multiple blue wires and red wire properly connected. Evaluated basement mechanical area with exposed HVAC ductwork and electrical infrastructure to assess system accessibility and replacement requirements for aging R22 equipment.
IC C.
IC C. Checked in
Conducted estimate for R22 refrigerant system with reported flat/no cooling condition. Inspected Nest thermostat installation and wiring configuration, documenting terminal connections including Y1, Y2, G, RC, W1/E, W2/AUX, and C terminals with multiple blue wires and red wire properly connected. Evaluated basement mechanical area with exposed HVAC ductwork and electrical infrastructure to assess system accessibility and replacement requirements for aging R22 equipment.
Belleville, MI 48111
Completed installation of Bradford White water heater in basement utility area. Unit properly positioned and secured with all copper supply lines connected, pressure relief valve installed, and metallic flue vent pipe routed through ceiling with appropriate elbows and support brackets. All connections tested and insulation applied to water lines to prevent condensation and heat loss.
Completed installation of Bradford White water heater in basement utility area. Unit properly positioned and secured with all copper supply lines connected, pressure relief valve installed, and metallic flue vent pipe routed through ceiling with appropriate elbows and support brackets. All connections tested and insulation applied to water lines to prevent condensation and heat loss.
IC W.
IC W. Checked in
Completed installation of Bradford White water heater in basement utility area. Unit properly positioned and secured with all copper supply lines connected, pressure relief valve installed, and metallic flue vent pipe routed through ceiling with appropriate elbows and support brackets. All connections tested and insulation applied to water lines to prevent condensation and heat loss.
Belleville, MI 48111
Responded to no cooling complaint on 30-year-old residential air conditioning system. Upon arrival, confirmed outdoor unit fan motor was operating but system was not producing adequate cooling. Performed diagnostic evaluation of both indoor and outdoor components. Inspected 2005 Haier HC48JVAR outdoor condensing unit (48,000 BTU/h, R22 refrigerant) and Goodman furnace GMH950904CXAC. Given the advanced age of the equipment (30 years old, original to home) and the cost-effectiveness of repairs versus replacement, provided customer with options and recommendations. Documented equipment model and serial numbers with photographs for customer records. Customer opted to proceed with consultation only at this time.
Responded to no cooling complaint on 30-year-old residential air conditioning system. Upon arrival, confirmed outdoor unit fan motor was operating but system was not producing adequate cooling. Performed diagnostic evaluation of both indoor and outdoor components. Inspected 2005 Haier HC48JVAR outdoor condensing unit (48,000 BTU/h, R22 refrigerant) and Goodman furnace GMH950904CXAC. Given the advanced age of the equipment (30 years old, original to home) and the cost-effectiveness of repairs versus replacement, provided customer with options and recommendations. Documented equipment model and serial numbers with photographs for customer records. Customer opted to proceed with consultation only at this time.
IC T.
IC T. Checked in
Responded to no cooling complaint on 30-year-old residential air conditioning system. Upon arrival, confirmed outdoor unit fan motor was operating but system was not producing adequate cooling. Performed diagnostic evaluation of both indoor and outdoor components. Inspected 2005 Haier HC48JVAR outdoor condensing unit (48,000 BTU/h, R22 refrigerant) and Goodman furnace GMH950904CXAC. Given the advanced age of the equipment (30 years old, original to home) and the cost-effectiveness of repairs versus replacement, provided customer with options and recommendations. Documented equipment model and serial numbers with photographs for customer records. Customer opted to proceed with consultation only at this time.
Belleville, MI 48111
Completed prepaid air conditioner tune-up maintenance on residential AC system. Performed comprehensive inspection of indoor unit components, verified electrical connections and wiring integrity throughout the system, and inspected evaporator coil assembly. All components found operating within normal parameters with no deficiencies noted. System tested and confirmed functioning properly upon completion of scheduled maintenance.
Completed prepaid air conditioner tune-up maintenance on residential AC system. Performed comprehensive inspection of indoor unit components, verified electrical connections and wiring integrity throughout the system, and inspected evaporator coil assembly. All components found operating within normal parameters with no deficiencies noted. System tested and confirmed functioning properly upon completion of scheduled maintenance.
IC S.
IC S. Checked in
Completed prepaid air conditioner tune-up maintenance on residential AC system. Performed comprehensive inspection of indoor unit components, verified electrical connections and wiring integrity throughout the system, and inspected evaporator coil assembly. All components found operating within normal parameters with no deficiencies noted. System tested and confirmed functioning properly upon completion of scheduled maintenance.
Belleville, MI 48111
Responded to callback for reported water leak initially suspected to be from another source. Upon inspection, identified active water heater as leak source with visible moisture accumulation at base of unit on concrete floor. Documented water heater installation including all plumbing connections, copper supply lines with shut-off valves, metallic exhaust venting, and surrounding utility area components. Verified leak originating from water heater tank, confirmed with photographic evidence showing wet conditions at floor level around unit base. Notified customer of findings and recommended appropriate corrective action for water heater replacement.
Responded to callback for reported water leak initially suspected to be from another source. Upon inspection, identified active water heater as leak source with visible moisture accumulation at base of unit on concrete floor. Documented water heater installation including all plumbing connections, copper supply lines with shut-off valves, metallic exhaust venting, and surrounding utility area components. Verified leak originating from water heater tank, confirmed with photographic evidence showing wet conditions at floor level around unit base. Notified customer of findings and recommended appropriate corrective action for water heater replacement.
IC P.
IC P. Checked in
Responded to callback for reported water leak initially suspected to be from another source. Upon inspection, identified active water heater as leak source with visible moisture accumulation at base of unit on concrete floor. Documented water heater installation including all plumbing connections, copper supply lines with shut-off valves, metallic exhaust venting, and surrounding utility area components. Verified leak originating from water heater tank, confirmed with photographic evidence showing wet conditions at floor level around unit base. Notified customer of findings and recommended appropriate corrective action for water heater replacement.
Belleville, MI 48111
Completed comprehensive HVAC system evaluation for replacement estimate on existing American Standard Freedom 95 furnace installation. Documented current equipment condition including visible moisture accumulation on internal ductwork, assessed overall system configuration with copper refrigerant lines and electrical connections, and photographed installation setup to provide accurate replacement specifications for customer consideration.
Completed comprehensive HVAC system evaluation for replacement estimate on existing American Standard Freedom 95 furnace installation. Documented current equipment condition including visible moisture accumulation on internal ductwork, assessed overall system configuration with copper refrigerant lines and electrical connections, and photographed installation setup to provide accurate replacement specifications for customer consideration.
IC C.
IC C. Checked in
Completed comprehensive HVAC system evaluation for replacement estimate on existing American Standard Freedom 95 furnace installation. Documented current equipment condition including visible moisture accumulation on internal ductwork, assessed overall system configuration with copper refrigerant lines and electrical connections, and photographed installation setup to provide accurate replacement specifications for customer consideration.
Belleville, MI 48111
Responded to service call for water pooling under 4-year-old AC condenser unit following heavy rain. Upon inspection, found condenser unit unlevel, causing improper drainage from the condensate system. Verified condenser coils were clean and system was maintaining proper cooling operation with no refrigerant issues. Leveled outdoor condenser unit using adjustable pad, ensuring proper pitch for water drainage away from unit. Confirmed unit stability and tested system operation. System now draining properly with no water accumulation at base.
Responded to service call for water pooling under 4-year-old AC condenser unit following heavy rain. Upon inspection, found condenser unit unlevel, causing improper drainage from the condensate system. Verified condenser coils were clean and system was maintaining proper cooling operation with no refrigerant issues. Leveled outdoor condenser unit using adjustable pad, ensuring proper pitch for water drainage away from unit. Confirmed unit stability and tested system operation. System now draining properly with no water accumulation at base.
IC M.
IC M. Checked in
Responded to service call for water pooling under 4-year-old AC condenser unit following heavy rain. Upon inspection, found condenser unit unlevel, causing improper drainage from the condensate system. Verified condenser coils were clean and system was maintaining proper cooling operation with no refrigerant issues. Leveled outdoor condenser unit using adjustable pad, ensuring proper pitch for water drainage away from unit. Confirmed unit stability and tested system operation. System now draining properly with no water accumulation at base.
Belleville, MI 48111
# HVAC Service Report - No Cool Condition

Responded to service call for air conditioning system not cooling on unit over 10 years old. Upon arrival, performed visual inspection of outdoor condensing unit and electrical components. Found outdoor disconnect box mounted on exterior brick wall showing extensive weathering, rust, and corrosion throughout interior components. Circuit breaker and contactor housing displayed significant deterioration with rust stains streaking from connection points and exposed bare metal where paint had chipped away.

Opened equipment panels to inspect internal electrical connections and components. Located contactor assembly with brass terminal block showing signs of age and wear. Examined all wire connections including power supply wires and control circuit wiring. Found accumulated dirt, grime, and debris throughout equipment interior affecting multiple components. Metal surfaces displayed considerable discoloration and staining consistent with age and en
# HVAC Service Report - No Cool Condition

Responded to service call for air conditioning system not cooling on unit over 10 years old. Upon arrival, performed visual inspection of outdoor condensing unit and electrical components. Found outdoor disconnect box mounted on exterior brick wall showing extensive weathering, rust, and corrosion throughout interior components. Circuit breaker and contactor housing displayed significant deterioration with rust stains streaking from connection points and exposed bare metal where paint had chipped away.

Opened equipment panels to inspect internal electrical connections and components. Located contactor assembly with brass terminal block showing signs of age and wear. Examined all wire connections including power supply wires and control circuit wiring. Found accumulated dirt, grime, and debris throughout equipment interior affecting multiple components. Metal surfaces displayed considerable discoloration and staining consistent with age and en
IC E.
IC E. Checked in
# HVAC Service Report - No Cool Condition Responded to service call for air conditioning system not cooling on unit over 10 years old. Upon arrival, performed visual inspection of outdoor condensing unit and electrical components. Found outdoor disconnect box mounted on exterior brick wall showing extensive weathering, rust, and corrosion throughout interior components. Circuit breaker and contactor housing displayed significant deterioration with rust stains streaking from connection points and exposed bare metal where paint had chipped away. Opened equipment panels to inspect internal electrical connections and components. Located contactor assembly with brass terminal block showing signs of age and wear. Examined all wire connections including power supply wires and control circuit wiring. Found accumulated dirt, grime, and debris throughout equipment interior affecting multiple components. Metal surfaces displayed considerable discoloration and staining consistent with age and en
Belleville, MI 48111
Belleville, MI - Completed preventive maintenance agreement visit on Lennox ML14XC1S036-230C12 outdoor condensing unit containing R-410A refrigerant. Performed standard inspection of all accessible components, verified manufacturer specifications, and documented equipment nameplate information showing 3-ton capacity unit with 8 lbs 2 oz factory refrigerant charge. All systems operating within normal parameters at time of service.
IC S.
IC S. Checked in
Completed preventive maintenance agreement visit on Lennox ML14XC1S036-230C12 outdoor condensing unit containing R-410A refrigerant. Performed standard inspection of all accessible components, verified manufacturer specifications, and documented equipment nameplate information showing 3-ton capacity unit with 8 lbs 2 oz factory refrigerant charge. All systems operating within normal parameters at time of service.
Belleville, MI 48111
Performed cooling system tune-up and maintenance on properly functioning HVAC unit. Cleaned condenser coil to restore optimal airflow and heat transfer efficiency. Conducted comprehensive electrical diagnostics using digital multimeter, verifying capacitor functionality and measuring system amperage at 10.38A with proper voltage readings, confirming all electrical components operating within manufacturer specifications.
Performed cooling system tune-up and maintenance on properly functioning HVAC unit. Cleaned condenser coil to restore optimal airflow and heat transfer efficiency. Conducted comprehensive electrical diagnostics using digital multimeter, verifying capacitor functionality and measuring system amperage at 10.38A with proper voltage readings, confirming all electrical components operating within manufacturer specifications.
IC C.
IC C. Checked in
Performed cooling system tune-up and maintenance on properly functioning HVAC unit. Cleaned condenser coil to restore optimal airflow and heat transfer efficiency. Conducted comprehensive electrical diagnostics using digital multimeter, verifying capacitor functionality and measuring system amperage at 10.38A with proper voltage readings, confirming all electrical components operating within manufacturer specifications.
Belleville, MI 48111
Conducted estimate for complete HVAC system replacement due to severely deteriorated furnace with significant cabinet corrosion and air conditioning unit requiring R22 refrigerant charge. Performed temporary repair on AC system to maintain cooling operation until new equipment installation can be scheduled.
Conducted estimate for complete HVAC system replacement due to severely deteriorated furnace with significant cabinet corrosion and air conditioning unit requiring R22 refrigerant charge. Performed temporary repair on AC system to maintain cooling operation until new equipment installation can be scheduled.
IC P.
IC P. Checked in
Conducted estimate for complete HVAC system replacement due to severely deteriorated furnace with significant cabinet corrosion and air conditioning unit requiring R22 refrigerant charge. Performed temporary repair on AC system to maintain cooling operation until new equipment installation can be scheduled.
Belleville, MI 48111
# AC No Cool - Unit Not Starting

Responded to no cooling call on 10+ year old air conditioning system. Upon arrival, confirmed outdoor condensing unit was not operating. Inspected electrical connections at contactor assembly and found damaged contactor with signs of heat stress and discoloration around terminal points. Replaced failed contactor and verified all wire connections were secure at terminal block. Checked capacitor function and confirmed proper voltage supply to unit. Tested system operation and verified compressor and condenser fan motor started properly. Unit cooling normally at time of departure. Noted 16x25x4 air filter in place with installation date marked. Recommended monitoring system performance and scheduling routine maintenance due to age of equipment.
# AC No Cool - Unit Not Starting

Responded to no cooling call on 10+ year old air conditioning system. Upon arrival, confirmed outdoor condensing unit was not operating. Inspected electrical connections at contactor assembly and found damaged contactor with signs of heat stress and discoloration around terminal points. Replaced failed contactor and verified all wire connections were secure at terminal block. Checked capacitor function and confirmed proper voltage supply to unit. Tested system operation and verified compressor and condenser fan motor started properly. Unit cooling normally at time of departure. Noted 16x25x4 air filter in place with installation date marked. Recommended monitoring system performance and scheduling routine maintenance due to age of equipment.
IC S.
IC S. Checked in
# AC No Cool - Unit Not Starting Responded to no cooling call on 10+ year old air conditioning system. Upon arrival, confirmed outdoor condensing unit was not operating. Inspected electrical connections at contactor assembly and found damaged contactor with signs of heat stress and discoloration around terminal points. Replaced failed contactor and verified all wire connections were secure at terminal block. Checked capacitor function and confirmed proper voltage supply to unit. Tested system operation and verified compressor and condenser fan motor started properly. Unit cooling normally at time of departure. Noted 16x25x4 air filter in place with installation date marked. Recommended monitoring system performance and scheduling routine maintenance due to age of equipment.
Belleville, MI 48111
Completed full HVAC system installation including a 60,000 BTU gas furnace and 2.5-ton air conditioning condenser unit. The outdoor condenser was positioned on a concrete pad in the yard with proper clearances from the building structure. All refrigerant lines were connected, evacuated, and charged to manufacturer specifications using manifold gauges. The indoor furnace was installed in the utility closet with appropriate venting through PVC piping, gas supply line connections, and electrical wiring completed per code requirements. System startup procedures were performed, verifying proper operation of both heating and cooling functions. All mechanical connections were secured and tested for leaks, with the system left in full operational status ready for use.
Completed full HVAC system installation including a 60,000 BTU gas furnace and 2.5-ton air conditioning condenser unit. The outdoor condenser was positioned on a concrete pad in the yard with proper clearances from the building structure. All refrigerant lines were connected, evacuated, and charged to manufacturer specifications using manifold gauges. The indoor furnace was installed in the utility closet with appropriate venting through PVC piping, gas supply line connections, and electrical wiring completed per code requirements. System startup procedures were performed, verifying proper operation of both heating and cooling functions. All mechanical connections were secured and tested for leaks, with the system left in full operational status ready for use.
IC S.
IC S. Checked in
Completed full HVAC system installation including a 60,000 BTU gas furnace and 2.5-ton air conditioning condenser unit. The outdoor condenser was positioned on a concrete pad in the yard with proper clearances from the building structure. All refrigerant lines were connected, evacuated, and charged to manufacturer specifications using manifold gauges. The indoor furnace was installed in the utility closet with appropriate venting through PVC piping, gas supply line connections, and electrical wiring completed per code requirements. System startup procedures were performed, verifying proper operation of both heating and cooling functions. All mechanical connections were secured and tested for leaks, with the system left in full operational status ready for use.
Belleville, MI 48111
Completed installation of 2.5-ton air conditioning unit with matching evaporator coil in rear yard location. Performed mechanical installation, reconnected refrigerant lines, and verified system pressures using digital manifold gauges, confirming proper operating parameters and system integrity upon completion.
Completed installation of 2.5-ton air conditioning unit with matching evaporator coil in rear yard location. Performed mechanical installation, reconnected refrigerant lines, and verified system pressures using digital manifold gauges, confirming proper operating parameters and system integrity upon completion.
IC S.
IC S. Checked in
Completed installation of 2.5-ton air conditioning unit with matching evaporator coil in rear yard location. Performed mechanical installation, reconnected refrigerant lines, and verified system pressures using digital manifold gauges, confirming proper operating parameters and system integrity upon completion.
Belleville, MI 48111
Belleville, MI - Responded to no cooling complaint on Lennox unit model M296IUH070XV36B. Found evaporator coil frozen solid in air handler, indicating restricted airflow or low refrigerant charge. Documented equipment nameplate specifications and system condition upon arrival for service records.
IC L.
IC L. Checked in
Responded to no cooling complaint on Lennox unit model M296IUH070XV36B. Found evaporator coil frozen solid in air handler, indicating restricted airflow or low refrigerant charge. Documented equipment nameplate specifications and system condition upon arrival for service records.
Belleville, MI 48111
Start Saving Today With

Membership Perks

Comfort Club Maintenance Plan

Guaranteed Quality & Reliable Service Learn More
Start Saving Today With

Membership Perks

What To Expect

Discover the Iceberg Heating & Cooling Difference

24/7 Emergency Service

HVAC emergencies often happen on nights, weekends, and holidays, so you can trust us to be there no matter when you need us.

Done Right, Done Fast, Done On Time

Iceberg Heating & Cooling’s trustworthy technicians arrive when they say they will and get the job done right the first time.

Highly Trained Technicians

Our highly trained experts have the knowledge and training to deliver reliable and quality services.

Comfort Guaranteed

We stand behind our work and are dedicated to always making it right, providing exceptional service every time.

Upfront Pricing

You can trust that we will always provide a straightforward and fair price for our services without unexpected fees or upcharges.

We Are Here When You Need Us Most

Our customer service is unrivaled, and our technicians go the extra mile to ensure help you need when you need it most.

24/7 Emergency Service

HVAC emergencies often happen on nights, weekends, and holidays, so you can trust us to be there no matter when you need us.

Done Right, Done Fast, Done On Time

Iceberg Heating & Cooling’s trustworthy technicians arrive when they say they will and get the job done right the first time.

Highly Trained Technicians

Our highly trained experts have the knowledge and training to deliver reliable and quality services.

Comfort Guaranteed

We stand behind our work and are dedicated to always making it right, providing exceptional service every time.

Upfront Pricing

You can trust that we will always provide a straightforward and fair price for our services without unexpected fees or upcharges.

We Are Here When You Need Us Most

Our customer service is unrivaled, and our technicians go the extra mile to ensure help you need when you need it most.

Review Image
Our Reviews

See What Your Neighbors Are Saying

I just want to say that Iceberg Heating & Cooling always does a very professional job and the technicians are very knowledgeable and very personable. I always feel like I am their #1 customer. I would recommend their service without any hesitations.

Dennis K.

Dennis K.

The staff is very helpful and friendly. They won’t recommend any unnecessary work either. I’ve been with them for the last 2 years and I feel that I am in good hands with them.

Justin K.

Justin K.

Outstanding service with very skilled professionals. I couldn’t be more pleased with every aspect of my recent installation of an air conditioning and furnace unit. These folks are top notch and I would highly recommend them!

Victoria L.

Victoria L.

The installation was without a hitch. Your service is impeccable. I have absolutely no problem. I recommend you to everybody I talk to. In fact, my daughter had a furnace and air conditioner put in based off of our experience. I’m very pleased.

Ray N.

Ray N.

It’s like family to me, everyone that’s included with Iceberg. They’ve always been there for our needs. No matter what time of day it was they would always call us back and meet our needs. They’re always there for us. They do it from their heart…

Maryanne F.

Maryanne F.