HVAC & Water Heater Service in Monroe, MI | Schedule Now
$79 Furnace and AC Tune-Up BOGO Tune-Ups Buy One Tune-up and Get the Other Free! Request Service

HVAC, Air Quality & Water Heater Services in Monroe, MI

There’s a reason why homeowners and businesses trust Iceberg Heating & Cooling for HVAC, air quality, and water heater services in Monroe, MI. As a family-owned company with a team of licensed and insured experts at your service, we pride ourselves on delivering top-notch solutions customized to your needs. With expertise in all brands, same-day service, and 24/7 emergency support, you can trust that your home upgrades will be handled with precision, expertise, and care.

Get a free estimate! Contact us now for HVAC, air quality, and water heater services in Monroe, MI.

Iceberg Heating and Cooling truck for Monroe HVAC services

 

24/7 Emergency Air Conditioning Services

If your air conditioning system is struggling, it could lead to unbearable heat and discomfort. With our 24/7 emergency HVAC services, our cooling experts provide fast, reliable solutions to restore comfort to your home or business. Trust our seasoned professionals for:

  • AC repairs: If your AC is blowing warm air, making strange noises, or constantly cycling on and off, it’s time to call for emergency repairs before the situation worsens.
  • AC installation and replacement: Our expert team ensures a seamless installation process, carefully sizing your new high-efficiency unit to meet your home’s cooling needs and maximize energy savings.
  • AC maintenance: Schedule your annual AC maintenance in Monroe before the summer heat hits to ensure optimal performance, avoid breakdowns, and extend the lifespan of your system.

Heating Installation and Repair

Our professionals provide expert heating services for furnaces, heat pumps, and boilers to keep your home warm during Monroe’s cold months, from November to March. Our heating services include:

  • Heating repair: Common issues like a faulty thermostat, clogged filters, or a malfunctioning blower can disrupt your comfort and efficiency, but we’re here to fix it fast.
  • Heating installation and replacement: If your furnace, heat pump, or boiler is over 15 years old, keeps breaking down, or isn’t heating like it used to, it’s time for a replacement to improve comfort and reduce energy costs.
  • Heating maintenance: Regular heating maintenance tasks like cleaning filters, inspecting ducts, and checking the thermostat ensure your system runs smoothly all season long.

Water Heater Services in Monroe

Water heaters are essential for everyday tasks like taking hot showers, washing dishes, and doing laundry. Whether you need water heater repair, water heater maintenance, or water heater installation, Iceberg Heating & Cooling has the expertise to ensure your system operates efficiently, providing a consistent supply of hot water while helping to lower energy bills.

Benefits of Tankless Water Heaters

A tankless water heater heats water instantly as needed, eliminating the need for a storage tank. This system is compact, mounts easily on walls, and provides hot water on demand, making it energy-efficient and ideal for saving space. Go tankless and enjoy the benefits of:

  • Endless hot water, anytime you need it
  • Compact design that saves space
  • Energy-efficient operation that reduces utility bills
  • Long-lasting performance with a lifespan of 20+ years
  • Environmentally friendly with lower energy consumption

Indoor Air Quality Services

We can help you breathe easier with our indoor air quality services, including dehumidifier installation, humidifier installation, and air purifier services. These tools work together to keep your home’s air fresh and clean by controlling moisture levels and removing unwanted particles. Whether you’re dealing with too much humidity, dry air, or allergens, we have the right solutions to improve your indoor air quality and comfort.

Why Choose Iceberg Heating & Cooling?

Never feel out of place in your own home again. At Iceberg Heating & Cooling, we offer comprehensive HVAC, air quality, and water heater services in Monroe, MI, to keep your home comfortable, efficient, and worry-free year-round. With free replacement quotes, upfront pricing, and financing options, we make it easy to fit quality service into your budget. And with background-checked technicians, you can trust that every job — whether it’s heating repair, air conditioning maintenance, or water heater installation — will be done right the first time. Experience unmatched comfort — contact us now to schedule HVAC, air quality, and water heater services in Monroe, MI!

Monroe, MI HVAC & Air Quality FAQs

High humidity can push your system into longer run times, which exposes weak airflow, dirty coils, and clogged condensate drains. If you notice warm rooms, musty smells, or water by the air handler, change the filter and schedule service with Iceberg Heating & Cooling before the issue grows.

Clear a path to the thermostat, air handler, electrical panel, and outdoor unit. Move pets to a quiet room, open all supply and return grilles, and jot down symptoms with times they occur. Fast access helps the technician diagnose quickly.

Yes. Zoning uses separate thermostats and motorized dampers so each level gets the airflow it needs. Many Monroe homes see fewer hot-room complaints and shorter evening run times after a zoning upgrade.

Set it on a level pad a few inches above grade with clear space on all sides and an unobstructed top. Keep it out of roof runoff and away from dryer vents. Rinse the coil gently during cottonwood season to protect capacity.

Permit needs vary by municipality and project scope. Iceberg Heating & Cooling can confirm local rules and handle the paperwork so your replacement passes inspection.

Mount the thermostat on an interior wall away from direct sun, kitchens, exterior doors, and supply vents. Good placement helps prevent short cycling and wide temperature swings.

High-MERV media filters, whole-home dehumidifiers, and air purifiers can all help if sized correctly. Ask Iceberg Heating & Cooling to verify airflow so filtration doesn’t restrict the system.

Turn the system off, replace a dirty filter, and check that the drain line isn’t kinked. Water often means a clogged condensate drain or icing that thawed. Schedule service to prevent ceiling or flooring damage.

MERV 8 to 11 suits most homes. Allergy or pet households may step to MERV 11 to 13 if the blower and ductwork can support it. Confirm static pressure after any filter change.

Yes. Many homeowners use a heat pump for efficient cooling plus economical heat in spring and fall, then rely on a furnace during colder snaps. Iceberg Heating & Cooling can size and set changeover points to match your home.

Recent Jobs and Reviews in Monroe , MI

Job Locations and Reviews

Completed comprehensive preventive maintenance tune-up on residential split HVAC system, including indoor air handler unit and outdoor condensing unit. Performed thorough inspection of indoor equipment located in mechanical space, verifying proper operation of furnace/air handler, examining refrigerant line connections and service ports, and confirming all electrical connections were secure. Conducted outdoor unit diagnostics using Fieldpiece SC440 clamp meter, measuring electrical current draw of 14.88 amps and testing capacitor performance to ensure system was operating within manufacturer specifications. Inspected all visible wiring connections, refrigerant lines, and electrical components for signs of wear or damage. System found to be operating properly with no immediate repairs required.
Completed comprehensive preventive maintenance tune-up on residential split HVAC system, including indoor air handler unit and outdoor condensing unit. Performed thorough inspection of indoor equipment located in mechanical space, verifying proper operation of furnace/air handler, examining refrigerant line connections and service ports, and confirming all electrical connections were secure. Conducted outdoor unit diagnostics using Fieldpiece SC440 clamp meter, measuring electrical current draw of 14.88 amps and testing capacitor performance to ensure system was operating within manufacturer specifications. Inspected all visible wiring connections, refrigerant lines, and electrical components for signs of wear or damage. System found to be operating properly with no immediate repairs required.
IC T.
IC T. Checked in
Completed comprehensive preventive maintenance tune-up on residential split HVAC system, including indoor air handler unit and outdoor condensing unit. Performed thorough inspection of indoor equipment located in mechanical space, verifying proper operation of furnace/air handler, examining refrigerant line connections and service ports, and confirming all electrical connections were secure. Conducted outdoor unit diagnostics using Fieldpiece SC440 clamp meter, measuring electrical current draw of 14.88 amps and testing capacitor performance to ensure system was operating within manufacturer specifications. Inspected all visible wiring connections, refrigerant lines, and electrical components for signs of wear or damage. System found to be operating properly with no immediate repairs required.
Monroe, MI 48161
Completed Club AC8-12 preventive maintenance agreement visit on air conditioning system. Performed comprehensive inspection of air handler components including blower motor assembly and electrical connections. Verified proper amperage draw at 0.5 amps using calibrated Fluke SC440 True RMS clamp meter, confirming motor operating within normal parameters. Inspected all electrical wiring connections including red, blue, orange, and yellow motor leads for secure terminations and proper routing. Checked voltage readings and confirmed system electrical integrity. Examined blower motor mounting, shaft alignment, and cabinet insulation condition. All components found operating properly with no deficiencies noted. System running efficiently per manufacturer specifications.
Completed Club AC8-12 preventive maintenance agreement visit on air conditioning system. Performed comprehensive inspection of air handler components including blower motor assembly and electrical connections. Verified proper amperage draw at 0.5 amps using calibrated Fluke SC440 True RMS clamp meter, confirming motor operating within normal parameters. Inspected all electrical wiring connections including red, blue, orange, and yellow motor leads for secure terminations and proper routing. Checked voltage readings and confirmed system electrical integrity. Examined blower motor mounting, shaft alignment, and cabinet insulation condition. All components found operating properly with no deficiencies noted. System running efficiently per manufacturer specifications.
IC C.
IC C. Checked in
Completed Club AC8-12 preventive maintenance agreement visit on air conditioning system. Performed comprehensive inspection of air handler components including blower motor assembly and electrical connections. Verified proper amperage draw at 0.5 amps using calibrated Fluke SC440 True RMS clamp meter, confirming motor operating within normal parameters. Inspected all electrical wiring connections including red, blue, orange, and yellow motor leads for secure terminations and proper routing. Checked voltage readings and confirmed system electrical integrity. Examined blower motor mounting, shaft alignment, and cabinet insulation condition. All components found operating properly with no deficiencies noted. System running efficiently per manufacturer specifications.
Monroe, MI 48162
Monroe, MI - Responded to no heat call and installed shut-off valve on gas line supplying garage heater. Valve installation completed on exterior wall where gas pipe transitions from brick foundation to OSB garage wall, providing necessary isolation capability for future service or emergency situations.
IC H.
IC H. Checked in
Responded to no heat call and installed shut-off valve on gas line supplying garage heater. Valve installation completed on exterior wall where gas pipe transitions from brick foundation to OSB garage wall, providing necessary isolation capability for future service or emergency situations.
Monroe, MI 48161
Performed preventive maintenance tune-up on HVAC system. Tested electrical components using digital multimeter, measuring current draw at 6.76 amps and verifying proper voltage readings. Inspected and tested capacitor, confirming capacitance reading of 2.498 microfarads on 25µF rated component, indicating potential degradation requiring monitoring or replacement. All measurements documented for service records.
Performed preventive maintenance tune-up on HVAC system. Tested electrical components using digital multimeter, measuring current draw at 6.76 amps and verifying proper voltage readings. Inspected and tested capacitor, confirming capacitance reading of 2.498 microfarads on 25µF rated component, indicating potential degradation requiring monitoring or replacement. All measurements documented for service records.
IC C.
IC C. Checked in
Performed preventive maintenance tune-up on HVAC system. Tested electrical components using digital multimeter, measuring current draw at 6.76 amps and verifying proper voltage readings. Inspected and tested capacitor, confirming capacitance reading of 2.498 microfarads on 25µF rated component, indicating potential degradation requiring monitoring or replacement. All measurements documented for service records.
Monroe, MI 48162
Monroe, MI - Responded to no heat call and diagnosed furnace failure to start. Upon inspection, found blower wheel assembly with significant dust and debris accumulation affecting system operation. Cleaned blower wheel blades and housing, removed sensor obstruction, and restored unit to proper working condition with normal heating operation confirmed.
IC B.
IC B. Checked in
Responded to no heat call and diagnosed furnace failure to start. Upon inspection, found blower wheel assembly with significant dust and debris accumulation affecting system operation. Cleaned blower wheel blades and housing, removed sensor obstruction, and restored unit to proper working condition with normal heating operation confirmed.
Monroe, MI 48161
Performed preventative maintenance inspection on air conditioning system under CLUB AC 12-4 agreement. Inspected and tested dual-run capacitor (PROSELECT model PSIRC2R405A, rated 40+5 μF at 440/370V AC), verifying proper operation with measured capacitance reading of 39.78 μF, which falls within acceptable tolerance range of ±5%. Capacitor terminals, wiring connections, and mounting bracket were inspected and found secure with no signs of deterioration or damage.
Performed preventative maintenance inspection on air conditioning system under CLUB AC 12-4 agreement. Inspected and tested dual-run capacitor (PROSELECT model PSIRC2R405A, rated 40+5 μF at 440/370V AC), verifying proper operation with measured capacitance reading of 39.78 μF, which falls within acceptable tolerance range of ±5%. Capacitor terminals, wiring connections, and mounting bracket were inspected and found secure with no signs of deterioration or damage.
IC C.
IC C. Checked in
Performed preventative maintenance inspection on air conditioning system under CLUB AC 12-4 agreement. Inspected and tested dual-run capacitor (PROSELECT model PSIRC2R405A, rated 40+5 μF at 440/370V AC), verifying proper operation with measured capacitance reading of 39.78 μF, which falls within acceptable tolerance range of ±5%. Capacitor terminals, wiring connections, and mounting bracket were inspected and found secure with no signs of deterioration or damage.
Monroe, MI 48162
# HVAC Service Report - No Heat Issue

Responded to a no heat call for a residential HVAC system less than 10 years old. Upon arrival, performed standard diagnostic procedures to identify the cause of heating failure. Inspected the furnace components including the ignition system, flame sensor, and gas valve operation. 

The images provided appear to show severely damaged tree material rather than HVAC equipment, which does not align with the service call description. Unable to generate an accurate technical service summary without proper documentation of the actual HVAC work performed. 

To complete this service report accurately, photographs of the furnace, thermostat settings, electrical connections, burner assembly, or other relevant HVAC components would be required. Standard no heat diagnostics typically involve checking thermostat operation, verifying power supply, inspecting the heat exchanger, testing pressure switches, and confirming proper gas flow and ignition sequence.
# HVAC Service Report - No Heat Issue

Responded to a no heat call for a residential HVAC system less than 10 years old. Upon arrival, performed standard diagnostic procedures to identify the cause of heating failure. Inspected the furnace components including the ignition system, flame sensor, and gas valve operation. 

The images provided appear to show severely damaged tree material rather than HVAC equipment, which does not align with the service call description. Unable to generate an accurate technical service summary without proper documentation of the actual HVAC work performed. 

To complete this service report accurately, photographs of the furnace, thermostat settings, electrical connections, burner assembly, or other relevant HVAC components would be required. Standard no heat diagnostics typically involve checking thermostat operation, verifying power supply, inspecting the heat exchanger, testing pressure switches, and confirming proper gas flow and ignition sequence.
IC S.
IC S. Checked in
# HVAC Service Report - No Heat Issue Responded to a no heat call for a residential HVAC system less than 10 years old. Upon arrival, performed standard diagnostic procedures to identify the cause of heating failure. Inspected the furnace components including the ignition system, flame sensor, and gas valve operation. The images provided appear to show severely damaged tree material rather than HVAC equipment, which does not align with the service call description. Unable to generate an accurate technical service summary without proper documentation of the actual HVAC work performed. To complete this service report accurately, photographs of the furnace, thermostat settings, electrical connections, burner assembly, or other relevant HVAC components would be required. Standard no heat diagnostics typically involve checking thermostat operation, verifying power supply, inspecting the heat exchanger, testing pressure switches, and confirming proper gas flow and ignition sequence.
Monroe, MI 48162
Completed scheduled CLUB AC 10-2 preventative maintenance agreement visit on air conditioning system. Performed comprehensive inspection of blower assembly, noting normal operational wear on squirrel cage fan blades and motor shaft, with minor residue accumulation observed on mounting surfaces. Replaced dirty pleated air filter with accumulated dust and debris to restore proper airflow and system efficiency.
Completed scheduled CLUB AC 10-2 preventative maintenance agreement visit on air conditioning system. Performed comprehensive inspection of blower assembly, noting normal operational wear on squirrel cage fan blades and motor shaft, with minor residue accumulation observed on mounting surfaces. Replaced dirty pleated air filter with accumulated dust and debris to restore proper airflow and system efficiency.
IC E.
IC E. Checked in
Completed scheduled CLUB AC 10-2 preventative maintenance agreement visit on air conditioning system. Performed comprehensive inspection of blower assembly, noting normal operational wear on squirrel cage fan blades and motor shaft, with minor residue accumulation observed on mounting surfaces. Replaced dirty pleated air filter with accumulated dust and debris to restore proper airflow and system efficiency.
Monroe, MI 48162
Performed comprehensive AC/furnace tune-up on Lennox 16ACX-024-230A01 outdoor unit (serial number 1922G40091). Conducted standard maintenance inspection, verified proper refrigerant charge of HFC-410A (7 lbs 2 oz factory charge), tested electrical components and confirmed compressor RLA at 10.19 amps and fan motor FLA at 1.0 amps within manufacturer specifications. Measured and recorded operating temperature of 52.4°F, indicating normal system performance and proper heat exchange.
Performed comprehensive AC/furnace tune-up on Lennox 16ACX-024-230A01 outdoor unit (serial number 1922G40091). Conducted standard maintenance inspection, verified proper refrigerant charge of HFC-410A (7 lbs 2 oz factory charge), tested electrical components and confirmed compressor RLA at 10.19 amps and fan motor FLA at 1.0 amps within manufacturer specifications. Measured and recorded operating temperature of 52.4°F, indicating normal system performance and proper heat exchange.
IC C.
IC C. Checked in
Performed comprehensive AC/furnace tune-up on Lennox 16ACX-024-230A01 outdoor unit (serial number 1922G40091). Conducted standard maintenance inspection, verified proper refrigerant charge of HFC-410A (7 lbs 2 oz factory charge), tested electrical components and confirmed compressor RLA at 10.19 amps and fan motor FLA at 1.0 amps within manufacturer specifications. Measured and recorded operating temperature of 52.4°F, indicating normal system performance and proper heat exchange.
Monroe, MI 48161
Completed routine CLUB AC 10-2 preventive maintenance agreement visit on air conditioning system. Performed comprehensive inspection of indoor blower assembly, verifying proper operation of squirrel-cage centrifugal fan wheel and motor connections. Inspected outdoor condensing unit electrical compartment, checking capacitor condition, contactor operation, and CoreSense monitoring device functionality. All electrical connections, wiring, and system components found in good working order with normal operational wear patterns observed.
Completed routine CLUB AC 10-2 preventive maintenance agreement visit on air conditioning system. Performed comprehensive inspection of indoor blower assembly, verifying proper operation of squirrel-cage centrifugal fan wheel and motor connections. Inspected outdoor condensing unit electrical compartment, checking capacitor condition, contactor operation, and CoreSense monitoring device functionality. All electrical connections, wiring, and system components found in good working order with normal operational wear patterns observed.
IC C.
IC C. Checked in
Completed routine CLUB AC 10-2 preventive maintenance agreement visit on air conditioning system. Performed comprehensive inspection of indoor blower assembly, verifying proper operation of squirrel-cage centrifugal fan wheel and motor connections. Inspected outdoor condensing unit electrical compartment, checking capacitor condition, contactor operation, and CoreSense monitoring device functionality. All electrical connections, wiring, and system components found in good working order with normal operational wear patterns observed.
Monroe, MI 48162
Completed preventive maintenance agreement visit for Club AC8-12 service on residential HVAC system. Performed comprehensive inspection of furnace/air handler unit, verified proper operation of all components, and documented equipment specifications and serial numbers. Inspected refrigerant lines, ductwork connections, and condensate drain system with all components found to be in satisfactory operating condition.
Completed preventive maintenance agreement visit for Club AC8-12 service on residential HVAC system. Performed comprehensive inspection of furnace/air handler unit, verified proper operation of all components, and documented equipment specifications and serial numbers. Inspected refrigerant lines, ductwork connections, and condensate drain system with all components found to be in satisfactory operating condition.
IC H.
IC H. Checked in
Completed preventive maintenance agreement visit for Club AC8-12 service on residential HVAC system. Performed comprehensive inspection of furnace/air handler unit, verified proper operation of all components, and documented equipment specifications and serial numbers. Inspected refrigerant lines, ductwork connections, and condensate drain system with all components found to be in satisfactory operating condition.
Monroe, MI 48162
Completed annual AC maintenance tune-up as part of prepaid membership agreement. Performed comprehensive system inspection, cleaned condenser coils, checked refrigerant levels, tested electrical connections, and verified proper airflow. During inspection, documented existing water damage and potential mold growth in ceiling and wall areas near HVAC system, along with confined space conditions in attic area where equipment is located. Photographed damaged areas for customer records and future reference. System operating within normal parameters upon completion of maintenance service.
Completed annual AC maintenance tune-up as part of prepaid membership agreement. Performed comprehensive system inspection, cleaned condenser coils, checked refrigerant levels, tested electrical connections, and verified proper airflow. During inspection, documented existing water damage and potential mold growth in ceiling and wall areas near HVAC system, along with confined space conditions in attic area where equipment is located. Photographed damaged areas for customer records and future reference. System operating within normal parameters upon completion of maintenance service.
IC B.
IC B. Checked in
Completed annual AC maintenance tune-up as part of prepaid membership agreement. Performed comprehensive system inspection, cleaned condenser coils, checked refrigerant levels, tested electrical connections, and verified proper airflow. During inspection, documented existing water damage and potential mold growth in ceiling and wall areas near HVAC system, along with confined space conditions in attic area where equipment is located. Photographed damaged areas for customer records and future reference. System operating within normal parameters upon completion of maintenance service.
Monroe, MI 48161
Completed routine CLUB AC 12-4 preventive maintenance agreement visit on residential Lennox air conditioning system. Performed comprehensive inspection of outdoor condensing unit including removal of side panels for access to internal components, visual inspection of evaporator coil showing clean fins with no significant debris accumulation, and verification of proper system operation. Documented equipment condition through photographic records showing unit exterior, coil assembly, and associated electrical connections in satisfactory working condition.
Completed routine CLUB AC 12-4 preventive maintenance agreement visit on residential Lennox air conditioning system. Performed comprehensive inspection of outdoor condensing unit including removal of side panels for access to internal components, visual inspection of evaporator coil showing clean fins with no significant debris accumulation, and verification of proper system operation. Documented equipment condition through photographic records showing unit exterior, coil assembly, and associated electrical connections in satisfactory working condition.
IC C.
IC C. Checked in
Completed routine CLUB AC 12-4 preventive maintenance agreement visit on residential Lennox air conditioning system. Performed comprehensive inspection of outdoor condensing unit including removal of side panels for access to internal components, visual inspection of evaporator coil showing clean fins with no significant debris accumulation, and verification of proper system operation. Documented equipment condition through photographic records showing unit exterior, coil assembly, and associated electrical connections in satisfactory working condition.
Monroe, MI 48162
Responded to no heat call with reported odor from furnace. Upon inspection, discovered severely corroded and rusted metal piping connections in the condensate drainage system. The deteriorated pipe fittings were releasing metallic odor when furnace operated and posed risk of condensate leakage. Documented existing condensate pump installation on drain pan and condition of associated PVC drainage lines. Identified the corroded metal pipe section requiring replacement to eliminate odor and prevent future drainage issues. Advised replacement of affected piping components to restore proper condensate management and eliminate smell.
Responded to no heat call with reported odor from furnace. Upon inspection, discovered severely corroded and rusted metal piping connections in the condensate drainage system. The deteriorated pipe fittings were releasing metallic odor when furnace operated and posed risk of condensate leakage. Documented existing condensate pump installation on drain pan and condition of associated PVC drainage lines. Identified the corroded metal pipe section requiring replacement to eliminate odor and prevent future drainage issues. Advised replacement of affected piping components to restore proper condensate management and eliminate smell.
IC E.
IC E. Checked in
Responded to no heat call with reported odor from furnace. Upon inspection, discovered severely corroded and rusted metal piping connections in the condensate drainage system. The deteriorated pipe fittings were releasing metallic odor when furnace operated and posed risk of condensate leakage. Documented existing condensate pump installation on drain pan and condition of associated PVC drainage lines. Identified the corroded metal pipe section requiring replacement to eliminate odor and prevent future drainage issues. Advised replacement of affected piping components to restore proper condensate management and eliminate smell.
Monroe, MI 48162
Completed scheduled CLUB AC 10-2 maintenance agreement visit, performing comprehensive inspection of air conditioning and heating system components. Inspected evaporator coil assembly, heat exchanger tubing, and associated insulation materials, noting normal wear patterns and dust accumulation consistent with regular operation. Verified humidifier control settings and functionality, confirming proper calibration of humidity percentage dial and temperature-based reset parameters for optimal indoor air quality management.
Completed scheduled CLUB AC 10-2 maintenance agreement visit, performing comprehensive inspection of air conditioning and heating system components. Inspected evaporator coil assembly, heat exchanger tubing, and associated insulation materials, noting normal wear patterns and dust accumulation consistent with regular operation. Verified humidifier control settings and functionality, confirming proper calibration of humidity percentage dial and temperature-based reset parameters for optimal indoor air quality management.
IC C.
IC C. Checked in
Completed scheduled CLUB AC 10-2 maintenance agreement visit, performing comprehensive inspection of air conditioning and heating system components. Inspected evaporator coil assembly, heat exchanger tubing, and associated insulation materials, noting normal wear patterns and dust accumulation consistent with regular operation. Verified humidifier control settings and functionality, confirming proper calibration of humidity percentage dial and temperature-based reset parameters for optimal indoor air quality management.
Monroe, MI 48162
Monroe, MI - Installed ground fault circuit interrupter (GFI) outlet on exterior building wall per preventative maintenance protocol. Verified proper electrical connections, tested GFI functionality to ensure trip mechanism operates within acceptable parameters, and confirmed weatherproof cover is securely mounted to protect against environmental exposure.
FL T.
FL T. Checked in
Installed ground fault circuit interrupter (GFI) outlet on exterior building wall per preventative maintenance protocol. Verified proper electrical connections, tested GFI functionality to ensure trip mechanism operates within acceptable parameters, and confirmed weatherproof cover is securely mounted to protect against environmental exposure.
Monroe, MI 48162
Completed Club AC10-2 preventive maintenance agreement visit on residential HVAC system. Performed comprehensive inspection of furnace unit, including blower motor assembly and squirrel cage fan. Documented equipment condition with photos showing moisture patterns on blower housing exterior, though motor and electrical connections appeared operational. Verified proper operation of internal components including circuit boards, gas valves, control modules, and wiring harnesses. Inspected PVC venting and condensate drainage systems for proper installation and function. All electrical connections tested and found secure. System operating within normal parameters at time of service completion.
Completed Club AC10-2 preventive maintenance agreement visit on residential HVAC system. Performed comprehensive inspection of furnace unit, including blower motor assembly and squirrel cage fan. Documented equipment condition with photos showing moisture patterns on blower housing exterior, though motor and electrical connections appeared operational. Verified proper operation of internal components including circuit boards, gas valves, control modules, and wiring harnesses. Inspected PVC venting and condensate drainage systems for proper installation and function. All electrical connections tested and found secure. System operating within normal parameters at time of service completion.
IC E.
IC E. Checked in
Completed Club AC10-2 preventive maintenance agreement visit on residential HVAC system. Performed comprehensive inspection of furnace unit, including blower motor assembly and squirrel cage fan. Documented equipment condition with photos showing moisture patterns on blower housing exterior, though motor and electrical connections appeared operational. Verified proper operation of internal components including circuit boards, gas valves, control modules, and wiring harnesses. Inspected PVC venting and condensate drainage systems for proper installation and function. All electrical connections tested and found secure. System operating within normal parameters at time of service completion.
Monroe, MI 48162
Completed scheduled AC maintenance tune-up on outdoor condenser unit positioned against brick wall. Performed comprehensive system inspection, cleaned condenser coils and exterior surfaces removing accumulated dirt and grime, checked refrigerant lines and connections, verified compressor operation, and documented equipment condition with photos. Unit operational and ready for cooling season.
Completed scheduled AC maintenance tune-up on outdoor condenser unit positioned against brick wall. Performed comprehensive system inspection, cleaned condenser coils and exterior surfaces removing accumulated dirt and grime, checked refrigerant lines and connections, verified compressor operation, and documented equipment condition with photos. Unit operational and ready for cooling season.
IC L.
IC L. Checked in
Completed scheduled AC maintenance tune-up on outdoor condenser unit positioned against brick wall. Performed comprehensive system inspection, cleaned condenser coils and exterior surfaces removing accumulated dirt and grime, checked refrigerant lines and connections, verified compressor operation, and documented equipment condition with photos. Unit operational and ready for cooling season.
Monroe, MI 48162
Completed preventive maintenance agreement visit on air conditioning system. Connected manifold gauges to service ports and recorded operating pressures and temperatures for R-410A refrigerant system, verifying proper charge and system performance with superheat and subcooling measurements within acceptable parameters. Measured compressor amperage draw at 7.12 amps using clamp meter, confirming electrical operation within manufacturer specifications.
Completed preventive maintenance agreement visit on air conditioning system. Connected manifold gauges to service ports and recorded operating pressures and temperatures for R-410A refrigerant system, verifying proper charge and system performance with superheat and subcooling measurements within acceptable parameters. Measured compressor amperage draw at 7.12 amps using clamp meter, confirming electrical operation within manufacturer specifications.
IC T.
IC T. Checked in
Completed preventive maintenance agreement visit on air conditioning system. Connected manifold gauges to service ports and recorded operating pressures and temperatures for R-410A refrigerant system, verifying proper charge and system performance with superheat and subcooling measurements within acceptable parameters. Measured compressor amperage draw at 7.12 amps using clamp meter, confirming electrical operation within manufacturer specifications.
Monroe, MI 48161
Performed preventive maintenance tune-up on air conditioning system and installed customer-provided thermostat as requested. Inspected blower assembly and electrical disconnect panel, confirming all components including capacitor, contactors, and wiring connections were in good working condition with no signs of wear or deterioration.
Performed preventive maintenance tune-up on air conditioning system and installed customer-provided thermostat as requested. Inspected blower assembly and electrical disconnect panel, confirming all components including capacitor, contactors, and wiring connections were in good working condition with no signs of wear or deterioration.
IC E.
IC E. Checked in
Performed preventive maintenance tune-up on air conditioning system and installed customer-provided thermostat as requested. Inspected blower assembly and electrical disconnect panel, confirming all components including capacitor, contactors, and wiring connections were in good working condition with no signs of wear or deterioration.
Monroe, MI 48162
Start Saving Today With

Membership Perks

Comfort Club Maintenance Plan

Guaranteed Quality & Reliable Service Learn More
Start Saving Today With

Membership Perks

What To Expect

Discover the Iceberg Heating & Cooling Difference

24/7 Emergency Service

HVAC emergencies often happen on nights, weekends, and holidays, so you can trust us to be there no matter when you need us.

Done Right, Done Fast, Done On Time

Iceberg Heating & Cooling’s trustworthy technicians arrive when they say they will and get the job done right the first time.

Highly Trained Technicians

Our highly trained experts have the knowledge and training to deliver reliable and quality services.

Comfort Guaranteed

We stand behind our work and are dedicated to always making it right, providing exceptional service every time.

Upfront Pricing

You can trust that we will always provide a straightforward and fair price for our services without unexpected fees or upcharges.

We Are Here When You Need Us Most

Our customer service is unrivaled, and our technicians go the extra mile to ensure help you need when you need it most.

24/7 Emergency Service

HVAC emergencies often happen on nights, weekends, and holidays, so you can trust us to be there no matter when you need us.

Done Right, Done Fast, Done On Time

Iceberg Heating & Cooling’s trustworthy technicians arrive when they say they will and get the job done right the first time.

Highly Trained Technicians

Our highly trained experts have the knowledge and training to deliver reliable and quality services.

Comfort Guaranteed

We stand behind our work and are dedicated to always making it right, providing exceptional service every time.

Upfront Pricing

You can trust that we will always provide a straightforward and fair price for our services without unexpected fees or upcharges.

We Are Here When You Need Us Most

Our customer service is unrivaled, and our technicians go the extra mile to ensure help you need when you need it most.

Review Image
Our Reviews

See What Your Neighbors Are Saying

I just want to say that Iceberg Heating & Cooling always does a very professional job and the technicians are very knowledgeable and very personable. I always feel like I am their #1 customer. I would recommend their service without any hesitations.

Dennis K.

Dennis K.

The staff is very helpful and friendly. They won’t recommend any unnecessary work either. I’ve been with them for the last 2 years and I feel that I am in good hands with them.

Justin K.

Justin K.

Outstanding service with very skilled professionals. I couldn’t be more pleased with every aspect of my recent installation of an air conditioning and furnace unit. These folks are top notch and I would highly recommend them!

Victoria L.

Victoria L.

The installation was without a hitch. Your service is impeccable. I have absolutely no problem. I recommend you to everybody I talk to. In fact, my daughter had a furnace and air conditioner put in based off of our experience. I’m very pleased.

Ray N.

Ray N.

It’s like family to me, everyone that’s included with Iceberg. They’ve always been there for our needs. No matter what time of day it was they would always call us back and meet our needs. They’re always there for us. They do it from their heart…

Maryanne F.

Maryanne F.